Jeriyan SKU: 3M 27 OU İNVERTER
Jeriyan Multi-Split Series — R32 Jeriyan Multi Split 3M 27 Outdoor Unit
Other Variants of This Product:
Jeriyan Multi Split 3M 27 Outdoor Unit – DC Inverter
The 3M 27 outdoor unit, which manages 3 indoor units in a single system, is a powerful solution for three-room homes and small commercial areas with its 27,000 BTU total cooling capacity. Reaching the A+++ heating energy class with its superior SCOP value (5.1), the series offers maximum efficiency in the winter months too. Thanks to the independent control of each room, it provides a personalized comfort experience.
| General Information | |
|---|---|
| Power Supply | 220–240V, 1Ph, 50Hz |
| Compressor Type | Rotary DC Inverter |
| Refrigerant Type | R32 |
| GWP | 675 |
| Number of Supported Indoor Units | 3 |
| Cooling Performance | |
| Nominal Cooling Capacity | 27.000 (10.100–29.000) Btu/h |
| Nominal Cooling Consumption | 2.450 (235–3.220) W |
| Cooling Operating Current | 13.7 (2.2–14.3) A |
| Seasonal Cooling Design Power (Pdesignc) | 7.9 kW |
| SEER | 6.1 W/W |
| Cooling Energy Class | A++ |
| EER | 3.23 W/W |
| Heating Performance | |
| Nominal Heating Capacity | 28.000 (6.950–32.000) Btu/h |
| Nominal Heating Consumption | 2.100 (310–2.890) W |
| Heating Operating Current | 12.5 (2.6–12.9) A |
| Heating Design Power (Pdesignh) | 6.1 kW |
| SCOP (Temperate Climate Zone) | 5.1 W/W |
| Heating Energy Class | A+++ |
| COP | 3.91 W/W |
| Operating Conditions | |
| Outdoor Operating Temperature – Cooling | -15 ~ +50 °C |
| Outdoor Operating Temperature – Heating | -15 ~ +24 °C |
| Outdoor Unit Technical Data | |
| Maximum Operating Current | 17.5 A |
| Air Flow | 2.700 m³/h |
| Sound Pressure Level | 54 dB(A) |
| Power Level | 67 dB(A) |
| Net Dimensions (W×D×H) | 845×363×702 mm |
| Box Dimensions (W×D×H) | 965×395×775 mm |
| Net / Box Weight | 51.1 / 55.8 kg |
| Refrigerant Amount | 1.72 kg |
| Drain Outlet Diameter | OD∅25 |
| Piping & Installation | |
| Copper Pipe Diameter – Liquid (inch) | 3 × 1/4" |
| Copper Pipe Diameter – Gas (inch) | 3 × 3/8" |
| Copper Pipe Diameter – Liquid (mm) | 3 × Φ6.35 |
| Copper Pipe Diameter – Gas (mm) | 3 × Φ9.52 |
| Total Max Length for All Rooms | 60 m |
| Max Length for One Indoor Unit | 30 m |
| Max Height Difference Between Indoor-Outdoor Unit | 15 m |
| Max Height Difference Between Indoor Units | 10 m |
| Supply Cable | Dış Ünite |
| Charge-Free Copper Pipe Distance | 23 m |
| Additional Refrigerant Amount | 12 g/m |
| Circuit Breaker Rating | 1 FAZ 25 (B) |
| Supply Cable Cores × Cross-section | 3×4.0 adet×mm² |